Dimensions and tolerances EN 10253-4 (DIN 2615)
Unless otherwise indicated, dimensions are in mm.
Internal Ø | Tolerance on Diameter (D/ID) | Tolerance on wall thickness | F(a) | G(b) | Out of squareness and Alignment | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ø DN x DN1 | Ø D x D1 | EN 10253-4 | D2 | EN 10253-4 | D3* | EN 10253-4 | D4* | DIN 2615 | DIN 2615 | * | T | X(Q***) | |||||
15 x 15 | 21,3 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 25 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
20 x 20 | 26,9 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 29 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
20 x 15 | 26,9 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 29 +/-2 | 29 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
25 x 25 | 33,7 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
25 x 20 | 33,7 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | 38 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
25 x 15 | 33,7 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | 38 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
32 x 32 | 42,4 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
32 x 25 | 42,4 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
32 x 20 | 42,4 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
32 x 15 | 42,4 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
40 x 40 | 48,3 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
40 x 32 | 48,3 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
40 x 25 | 48,3 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
40 x 20 | 48,3 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
50 x 50 | 60,3 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
50 x 40 | 60,3 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 60 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
50 x 32 | 60,3 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
50 x 25 | 60,3 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 51 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
65 x 65 | 76,1 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
65 x 50 | 76,1 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 70 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
65 x 40 | 76,1 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 67 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
65 x 32 | 76,1 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 64 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
80 x 80 | 88,9 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
80 x 65 | 88,9 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 83 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
80 x 50 | 88,9 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 76 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
80 x 40 | 88,9 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 73 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
100 x 100 | 114,3 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
100 x 80 | 114,3 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 98 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
100 x 65 | 114,3 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 95 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
100 x 50 | 114,3 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 89 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
125 x 125 | 139,7 x 139,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
125 x 100 | 139,7 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 117 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
125 x 80 | 139,7 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 111 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
125 x 65 | 139,7 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 108 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
150 x 150 | 168,3 x 168,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
150 x 125 | 168,3 x 139,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 137 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
150 x 100 | 168,3 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 130 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
150 x 80 | 168,3 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 124 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
200 x 200 | 219,1 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
200 x 150 | 219,1 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 168 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
200 x 125 | 219,1 x 139,7 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 162 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
200 x 100 | 219,1 x 114,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 156 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
250 x 250 | 273 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
250 x 200 | 273 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 203 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
250 x 150 | 273 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 194 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
250 x 125 | 273 x 139,7 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 191 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
300 x 300 | 323,9 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
300 x 250 | 323,9 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 241 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
300 x 200 | 323,9 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 229 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
300 x 150 | 323,9 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 219 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
350 x 350 | 355,6 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
350 x 300 | 355,6 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 270 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
350 x 250 | 355,6 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 257 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
350 x 200 | 355,6 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 248 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
400 x 400 | 406,4 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
400 x 350 | 406,4 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 305 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
400 x 300 | 406,4 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 295 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
400 x 250 | 406,4 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 283 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
450 x 450 | 457 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
450 x 400 | 457 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 330 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
450 x 350 | 457 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 330 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
450 x 300 | 457 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 321 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
500 x 500 | 508 x 508 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
500 x 450 | 508 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 368 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
500 x 400 | 508 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 356 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
500 x 350 | 508 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 356 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
600 x 600 | 610 x 610 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
600 x 500 | 610 x 508 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 432 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
600 x 450 | 610 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 419 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
600 x 400 | 610 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 406 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
700 x 700 | 711 x 711 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 521 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
800 x 800 | 813 x 813 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 597 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
900 x 900 | 914 x 914 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 673 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater | ||
1000 x 1000 | 1016 x 1016 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 749 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
Unless otherwise indicated, dimensions are in mm.
Dimensions in brackets are valid only for DIN 2615.
Diameters:
Tolerances on outside diameter shall be measured at the welding ends.
In order to guarantee the regular flow of the fluid through the fitting, the internal diameter in any section of the tee shall be above 70 % of the internal diameter at the welding ends.
* Options that have to be specified in the order.
Out of roundness:
The out-of-roundness (0) shall be calculated in percentage, using the following equation:
0= (Dmax-Dmin)/Dx100, where:
Dmax = max. outside diameter D, measured in the same plane, in mm;
Dmin = min. outside diameter D, measured in the same plane, in mm;
D = specified outside diameter, in mm.
For fittings of outside diameter D ≤ 406,4 mm, out-of-roundness, shall be included in the limits of the diameter.
For fittings of outside diameter D > 406,4 mm and with D/T less than or equal to 100,
out-of-roundness shall not exceed 2 %.
For fittings with a D/T ratio > 100 the values for out-of-roundness shall be agreed at the time of enquiry and order.
For DIN 2615 see page 61 (DIN 2609).
Out of squareness:
*** DIN 2615, subject to agreement can be reduced to 0,5 % with a maximum of 0,5 mm.