Dimensioni e tolleranze EN 10253-4 (DIN 2615)
Se non diversamente indicato, le misure sono in mm.
Ø interno | Tolleranza sul Diametro D/DI | Tolleranza sullo spessore | F(a) | G(b) | Fuori squadra e allineamento | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ø DN x DN1 | Ø D x D1 | EN 10253-4 | D2 | EN 10253-4 | D3* | EN 10253-4 | D4* | DIN 2615 | DIN 2615 | * | T | X(Q***) | |||
15 x 15 | 21,3 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 25 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
20 x 20 | 26,9 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 29 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
20 x 15 | 26,9 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 29 +/-2 | 29 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
25 x 25 | 33,7 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
25 x 20 | 33,7 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | 38 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
25 x 15 | 33,7 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 38 +/-2 | 38 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
32 x 32 | 42,4 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
32 x 25 | 42,4 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
32 x 20 | 42,4 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
32 x 15 | 42,4 x 21,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 48 +/-2 | 48 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
40 x 40 | 48,3 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
40 x 32 | 48,3 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
40 x 25 | 48,3 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
40 x 20 | 48,3 x 26,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 57 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
50 x 50 | 60,3 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
50 x 40 | 60,3 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 60 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
50 x 32 | 60,3 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 57 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
50 x 25 | 60,3 x 33,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 64 +/-2 | 51 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
65 x 65 | 76,1 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
65 x 50 | 76,1 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 70 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
65 x 40 | 76,1 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 67 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
65 x 32 | 76,1 x 42,4 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 76 +/-2 | 64 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
80 x 80 | 88,9 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
80 x 65 | 88,9 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 83 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
80 x 50 | 88,9 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 76 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
80 x 40 | 88,9 x 48,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1%, max +/- 0,5 mm | +/- 0,4 mm | -12,5% / +15% | 86 +/-2 | 73 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
100 x 100 | 114,3 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
100 x 80 | 114,3 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 98 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
100 x 65 | 114,3 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 95 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
100 x 50 | 114,3 x 60,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 105 +/-2 | 89 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
125 x 125 | 139,7 x 139,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
125 x 100 | 139,7 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 117 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
125 x 80 | 139,7 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 111 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
125 x 65 | 139,7 x 76,1 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 124 +/-2 | 108 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
150 x 150 | 168,3 x 168,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
150 x 125 | 168,3 x 139,7 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 137 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
150 x 100 | 168,3 x 114,3 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 130 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
150 x 80 | 168,3 x 88,9 | D - 2 x w.t | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,5 % | -12,5% / +15% | 143 +/-2 | 124 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
200 x 200 | 219,1 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
200 x 150 | 219,1 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 168 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
200 x 125 | 219,1 x 139,7 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 162 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
200 x 100 | 219,1 x 114,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 178 +/-2 | 156 +/-2 | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
250 x 250 | 273 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
250 x 200 | 273 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 203 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
250 x 150 | 273 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 194 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
250 x 125 | 273 x 139,7 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 216 +/-5 (+/-3) | 191 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
300 x 300 | 323,9 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
300 x 250 | 323,9 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 241 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
300 x 200 | 323,9 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 229 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
300 x 150 | 323,9 x 168,3 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 254 +/-5 (+/-3) | 219 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
350 x 350 | 355,6 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
350 x 300 | 355,6 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 270 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
350 x 250 | 355,6 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 257 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
350 x 200 | 355,6 x 219,1 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 279 +/-5 (+/-3) | 248 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
400 x 400 | 406,4 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
400 x 350 | 406,4 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 305 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
400 x 300 | 406,4 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 295 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
400 x 250 | 406,4 x 273 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 305 +/-5 (+/-3) | 283 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
450 x 450 | 457 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
450 x 400 | 457 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 330 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
450 x 350 | 457 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 330 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
450 x 300 | 457 x 323,9 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 343 +/-5 (+/-3) | 321 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
500 x 500 | 508 x 508 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
500 x 450 | 508 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 368 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
500 x 400 | 508 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 356 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
500 x 350 | 508 x 355,6 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 381 +/-5 (+/-3) | 356 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
600 x 600 | 610 x 610 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
600 x 500 | 610 x 508 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 432 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
600 x 450 | 610 x 457 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 419 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
600 x 400 | 610 x 406,4 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | -12,5% / +15% | 432 +/-5 (+/-3) | 406 +/-5 (+/-3) | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
700 x 700 | 711 x 711 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 521 +/-5 (+/-3) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
800 x 800 | 813 x 813 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 597 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
900 x 900 | 914 x 914 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 673 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
1000 x 1000 | 1016 x 1016 | D - 2 x w.t. | +/-1% or 0,5 mm whichever is the greater | +/-0,75% or 0,3 mm whichever is the greater | +/-0,5% or 0,1 mm whichever is the greater | +/-1% | +/- 0,6 % | T<=10 mm: -0,35 mm / +15%T>10 mm: -0,5 mm / +15% | 749 +/-10 (+/-5) | - | X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater |
Se non diversamente indicato, le misure sono in mm.
Le dimensioni tra parentesi si riferiscono solo alla DIN 2615.
Diametri:
Le tolleranze sul diametro esterno devono essere misurate alle estremità.
Al fine di garantire il regolare flusso del fluido attraverso il raccordo, il diametro interno, in qualsiasi sezione del tee, deve essere almeno il 70% del diametro interno alle estremità.
* Opzioni che devono essere specificate nell’ordine.
Ovalizzazione:
L’ovalizzazione (0) è calcolata in percentuale, con la seguente equazione:
0 = (Dmax-Dmin)/Dx100, dove:
Dmax = max. diametro esterno D, misurato nello stesso piano, in mm;
Dmin = min. diametro esterno D, misurato nello stesso piano, in mm;
D = diametro esterno specificato, in mm.
Per raccordi di diametro esterno D ≤ 406,4 mm, l’ovalizzazione è inclusa nei limiti del diametro.
Per raccordi di diametro esterno D> 406,4 mm e con D / T <= 100, l’ovalizzazione
non deve superare il 2%.
Per i raccordi con un rapporto D / T > 100, i valori di ovalizzazione devono essere concordati al momento della richiesta e dell'ordine.
Per la DIN 2615 vedi la nota a pag. 60 (DIN 2609).
Fuori squadra:
*** DIN 2615, previo accordo può essere ridotta a 0,5% con un massimo di 0,5 mm